 Installation Communication cable Connect the MPPT Control to the Fangpusun MPPT Charge Controller with a VE.Direct cable.Note that this cable is not included and needs to be purchased separately. Power cable with inline fuse Wiring the supplied power cable is only necessary when the used MPPT...

    Product Details

    

    Installation 

    Communication cable 

    Connect the MPPT Control to the Fangpusun MPPT Charge Controller with a VE.Direct cable.Note that this cable is not included and needs to be purchased separately. 

    Power cable with inline fuse 

    Wiring the supplied power cable is only necessary when the used MPPT is an MPPT 75/50, 100/50 or 150/35, and its part number starts with SCC01. These earlier versions shut down at night. In this case, use the fused power cable to power the MPPT Control straight from the battery. This way, the MPPT Control stays powered while the MPPT is off, and the last received status, history and settings of the MPPT can be viewed when the sun is down. 

    Wiring this power cable is not necessary for all other models, neither for the SCC02 or later versions of the three mentioned models. 

    Wall mount enclosure 

    Optional wall mount enclosures are available to easily mount the MPPT control on a wall, instead of flush mounted through a panel. See our website for more information: http://www.fangpusun.com .

    Specifications

    MPPT Control
    Supply voltage range6,5 - 95 VDC (Battery powered)
    5V (VE.Direct powered)
    Current draw, back light off<4 mA
    Operating temperature range-20 - +50°C (0 - 120°F)
    Supported MPPTs
    ModelsAll models with VE.Direct port, except the
    BlueSolar MPPT 70/15
    Software versionAll software versions >= 1.12
    INSTALLATION & DIMENSIONS
    InstallationFlush mount
    Front63 mm diameter
    Front bezel69 x 69 mm
    (2.7 x 2.7 inch)
    Body diameter52mm
    (2.0 inch)
    Body depth 31mm
     (1.2 inch)
    ACCESSORIES
    Cables (included)cable with fuse for battery powered
    operation

    Buttons and display

    SETUPCancel / back
    SELECTSelect / confirm
     Change item or value
     OnThere is a connection with the MPPT.
    BlinkingThere was a connection with the MPPT but the connection is lost.
    The last know values will be shown.
     
    OffThere has not been a connection with a MPPT.

    Navigation 

    Status 

    The MPPT Control starts in the status menu. This shows the current status of the MPPT. 

    By pressing the up and down button, one can switch between the following values:

    PANEL POWER 
    PANEL VOLTAGE 
    YIELD TODAY 
    CHARGER ERRORThis is only visible when there is an actual error
    CHARGER STATEPossible value:
    OFF, FAULT, BULK, ABSORPTION, FLOAT
     
     
     
     
    BATTERY CURRENT 
    BATTERY VOLTAGE 
    LOAD OUTPUT STATEPossible  values:
    ON, OFF
    Only visible on MPPTs with a load output
     
     
     
     
     
    LOAD CURRENTOnly visible on MPPTs with a load output

     

    History

    By pressing SELECT in the status menu, the history menu is entered. Here, the history stored in the MPPT can be viewed. This contains both overall history and well as a day to day history. For MPPTs with software version up to 1.15, only a few history topics are available and the day to day history contains 2 days: the current day and the previous day. For MPPTs with software version 1.16 and onwards, this is a 30 day history. 

    When viewing values, one can select a different day by pressing the up and down button. The MPPT Control will first show the value for a short time, then the currently selected day, and then the value again. When viewing an overall history value, pressing the up or down button will cause the MPPT Control to show "TOTAL". 

    Pressing SETUP causes the MPPT Control to go back to the status menu topics when viewing topics or go back to the topics menu when viewing values.

    The topics are listed in the table below. Only topics marked with a * are visible in case of 2 day history.

    Overall topics
    TOTAL YIELD*The cumulative yield since the last history reset
    MAX PANEL VOLTAGEThe maximum panel voltage since the last history reset
    MAX BATTERY VOLTAGEThe maximum battery voltage since the last history reset
    MIN BATTERY VOLTAGEThe minimum battery voltage since the last history reset.
    (Only available for MPPT software version>= 1.17)
     
    LAST ERRORSThe last 4 errors since the last history reset.
    The number of blocks in the lower right of the screens determines
    which error is currently shown with 1 block being the latest and 4 blocks being the oldest.
                                Daily topics
    YIELD*The daily yield
    MAX POWER*The maximum power per day
    MAX PANEL VOLTAGEThe maximum panel voltage per day
    MAX BATTERY CURRENTThe maximum battery current per day
    MAX BATTERY VOLTAGEThe maximum battery voltage per day
    MIN BATTERY VOLTAGEThe minimum battery voltage per day
    BULK TIMEThe time spend in bulk per day
    ABSORPTION TIMEThe time spend in absorption per day
    FLOAT TIMEThe time spend in float per day
    LAST ERRORThe last 4 errors per day
    The number of blocks in the lower right of the screens determines
    which error is currently shown.

     

    Settings 

    By pressing SETUP for 2 seconds in the status menu, the settings menu is entered. Here, the settings of the MPPT and MPPT Control can be viewed and changed. First the topic is shown and when SELECT is pressed, the corresponding value is shown. When SELECT TO EDIT is OFF, the value is shown before it can be changed by pressing SELECT again. When SELECT TO EDIT is ON, the current value is shown and a new value can immediately be selected. When LOCK SETUP is ON, settings only be changed after setting LOCK SETUP to off.

    When editing a value, one can change its value by pressing the up and down buttons. When changing numeric values, pressing SELECT will go to the next digit, until the last digit. In this case, pressing SELECT will save the setting. When editing non numeric values, pressing SELECT will save the setting. 

    Pressing SETUP causes the MPPT Control to go back to the status menu topics when viewing topics or go back to the topics menu when viewing values.

    The settings are listed in the table below. See the manual of the MPPT for the exact meaning of the settings.

    01

    LOCK SETUP

    When this is ON, other settings cannot be changed. When trying to change a settin

    (except LOCK SETUP), the MPPT Control will show "LOCK" and show the value of that

    setting.

    02

    BATTERY VOLTAGE

    The battery voltage that the MPPT is working with. When the setting is AUTO, it will

    show the A character in front of the voltage.

    03

    BATTERY TYPE

    The battery type that the MPPT is working with. This can be set to FIXED or USER.

    When set to fixed, the rotary switch on the MPPT determines the actual battery type.

    When set to USER, all other charging related settings can be edited.

    It will be automatically set to USER when editing a charger related setting.

    04

    MAXIMUM CURRENT

    The maximum charging current

    05

    BULK TIME LIMIT

    The maximum time continuously spent in bulk

    06

    ABSORPTION TIME LIMIT

    The maximum time continuously spent in absorption

    07

    ABSORPTION VOLTAGE

    Battery voltage at which the MPPT switches to the absorption phase

    08

    FLOAT VOLTAGE

    Battery voltage at which the MPPT switches to the float phase

    09

    TEMP COMPENSATION

     

    10

    LOAD OUTPUT

    Load output operating mode.

    Possible values:

    OFF, AUTO, ALT1, ALT2, ON, USER1, USER2

    11

    LOAD SWITCH HIGH

    The high voltage level in case LOAD OUTPUT is set to USER1 or USER2

    12

    LOAD SWITCH LOW

    The low voltage level in case LOAD OUTPUT is set to USER1 or USER2

    13

    CLEAR HISTORY

    Clears the history of the MPPT

    14

    FACTORY DEFAULTS

    Resets the MPPT back to factory defaults

    15

    BACKLIGHT INTENSITY

    Sets the backlight intensity of the MPPT Control

    16

    BACKLIGHT ALWAYS ON

    Determines whether the backlight of the MPPT Control is always on

    17

    SCROLL SPEED

    Determines the scroll speed of the MPPT Control

    18

    SELECT TO EDIT

    When set to OFF, the MPPT Control first shows the value of a setting and SELECT has

    to be pressed to be able to edit the value

    19

    AUTO LOCK

    When set to ON, LOCK SETUP will be automatically set to ON, 2 minutes after changing

    a setting.

    20

    SOFTWARE VERSION

    The software version of the MPPT Control

    21

    SERIAL NR

    The serial number of the MPPT Control

    21

    MPPT SOFTWARE VERSION

    The software version of the MPPT

    21

    MPPT SERIAL NR

    The serial number of the MPPT